Purifiers (Oxygen Traps)

The OxiClear™ Gas Purifiers are oxygen-absorbing gas purifiers with high efficiency and low resistance to gas flow. OxiClear™ Gas Purifiers are primarily designed for applications involving gas chromatography, glove boxes and anaerobic experiments. They remove oxygen and trace amounts of water and organics from inert carrier gasses such as nitrogen, helium and argon. OxiClear™ purifiers are efficient to less than 5 ppb when the incoming oxygen concentration is 15 ppm or less. Furthermore, all models can withstand temperatures up to 100°C. All models are fitted with 60 micron stainless steel frits.

The OxiClear™ Gas Purifiers are offered in a large variety of designs and configurations:

Disposable purifiers
The OxiClear™ Disposable Gas Purifier is offered in th "inline" configuration, with either 1/4" or 1/8" brass mal tube compression fittings. It is capable of purifying the contents of 4-5 standard cylinders of 300 cubic feet, eas ily removing oxygen from inert carrier gasses down to less than 5 ppb. Offering a very low resistance to gas flow, .03 psi/(cc/second), the OxiClear™ Disposable Gaf Purifier will deliver 100 cc/second at a pressure drop o: only 0.3 psi. Flow rate to 5 liters per minute.

Refillable purifiers

Disposable purifiers

- Small size purifiers
- DGP-250-R1: with 1/4" fittings
- DGP-125-R1: with 1/8" fittings
- DGP-250-R2: with 1/4" fittings
- DGP-125-R2: with 1/8" fittings

- Large size purifiers
-DGP-R1-1000B: with 1/2" NPT fittings - capped
-DGP-R1-3000B: with 1/2" NPT fittings - capped

- Indicating Oxygen Traps (purifiers)

Now you are sure when your O2 purifier is expended and needs replacement (or refilling, if using a refillable model). Simply install the Indicating Oxygen Trap after the OxiClear™ purifier. When the color of the Indicating Oxygen Trap turns from light green to grey, it is time to change both the purifier and indicator. No more calculating or guesswork.

This safe, compact unit has a capacity of 40 cc of pure oxygen; it will remove oxygen from a full 200ft3 cylinder helium with 10 ppm oxygen (or several cylinders of higl purity helium). The heavy-walled inner glass tube of cats is protected from accidental breakage by the outer plasti tube. Maximum pressure is 100 psi. The Indicating Oxyj Trap is delivered in the active state, filled with helium. I recommended that the trap be purged before use with the gas you will be using. Approximate dimensions: 1 3/8"x 10 including fittings. Nickel-plated brass fittings.

 - IOT-250: with 1/4" fittings
 - IOT-125: with 1/8" fittings

Refillable purifiers

- In-line configuration
- RGP-250-R1: with 1/4" fittings
- RGP-125-R1: with 1/8" fittings

- Baseplate configuration
- RGPB-250-R1: with 1/4" fittings
- RGPB-125-R1: with 1/8" fittings

- Low carbon steel
- RGP-R1-300B: with 1/4" NPT fittings - capped
- RGP-R1-500B: with 1/4" NPT fittings - capped
- RGP-R1-1000B: with 1/2" NPT fittings - capped
- RGP-R1-3000B: with 1/2" NPT fittings - capped

- Stainless Steel purifiers
 All stainless Steel purifiers are made of 304 Stainless Steel, and are rated at a maximum operating pressure of 1800 psi (3000 psi upon request).
- RGP-R1-300: with 1/4" NPT fittings - capped
- RGP-R1-500: with 1/4" NPT fittings - capped
- RGP-R1-1000: with 1/2" NPT fittings - capped
- RGP-R1-3000: with 1/2" NPT fittings - capped
- RGP-R1-6600: with 1/2" NPT fittings - capped
- RGP-R1-10000: with 1/2" NPT fittings - capped
- RGP-R1-15600: with 1/2" NPT fittings - capped
- RGP-R1-20000: with 1/2" NPT fittings - capped